TM 9-4940-568-20
7-20
7-6. HYDRAULIC RESERVOIR REPLACEMENT (CONT).
5
10
9
11
12
6
7
8
4
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away from
open fire and use in well-ventilated area. If adhesive, solvent, or sealing compound
gets on skin or clothing, wash immediately with soap and water.
(9)
Apply sealing compound to threads of elbow fitting (12) and straight fitting (8)
(10)
Attach two hoses (9) and (10), tee-fitting (11) and elbow fitting (12) to hydraulic reservoir (4).
(11)
Attach two hoses (5) and (6), tee-fitting (7) and straight fitting (8) to hydraulic reservoir (4).
(12)
Fill hydraulic reservoir (4) (refer to Para 7-6a.).