TM 9-4940-568-20
3-24
Materials/Parts
Adhesive (Item 1, Appendix C)
Cable Ties (Item 10, Appendix C)
Primer (Item 29, Appendix C)
Tags, Identification (Item 40, Appendix C)
This task covers:
a. Removal
b. Repair
c. Installation
d. Follow-On Maintenance
INITIAL SETUP
Equipment Condition
FRS unloaded, (TM 9-4940-568-10)
Batteries disconnected, (TM 9-4940-568-10)
Tools and Special Tools
Tool Kit, General Mechanics: Automotive
(Item 30, Appendix G)
3-7. ELECTRICAL PIPING AND CLAMPS REPLACEMENT.
Materials/Parts Continued
Coupling, Female 1/2 in. (A/R)
(Item 2, Appendix F)
Coupling, Female 3/4 in. (Item 3, Appendix F)
Locknut (10) (Item 28, Appendix F)
a.
Removal.
1
2
Do not attempt to repair, cut, or replace any conduit or fixture without first removing all
wires to prevent personnel injury or damage to equipment.
NOTE
All electric piping is made up of either 3/4 in. or 1/2 in. schedule 40 electrical rigid PVC
conduit. Replace or repair using like sizes only.
Glued joints cannot be separated.
Remove cable ties as required.
(1)
Open junction box (1) located on each end of conduit assembly (2).