TM 9-4940-568-20
3-20
3-5. NATO SLAVE RECEPTACLE REPLACEMENT (CONT).
(4)
Remove four screws (10), lockwashers (11),
lockwashers (12), nuts (13) and slave
receptacle (14) from mount bracket (15).
Discard lockwashers.
b.
Installation.
NOTE
There are two nato slave
receptacles. Both are replaced
the same way unless noted other
wise.
Interior nato slave receptacle
shown.
Install wires as noted during
removal.
(1)
Install slave receptacle (14), four
lockwashers (11), screws (10), lockwashers
(12) and nuts (13) on mount bracket (15).
(2)
Install two wires (8), lockwasher (7) and
screw (6) on terminal (9).
(3)
Install two wires (4), lockwasher (3) and
screw (2) on terminal (5).
NOTE
Perform Step (4) if installing
exterior nato slave receptacle.
(4)
Install protective cover (1).
c.
Follow-On Maintenance:
Connect batteries, (TM 9-4940-568-10).
END OF TASK