TM 5-3825-230-14&PG-4.ELECTRICAL GROUND AND JUMPER WIRES FABRICATION.There are six ground and jumper wires in the electrical system. Locations are shown in the RPSTL, figures 32, 34, and35. Refer to paragraph 4-83 for terminal or connector installation.Table G-2. Ground and Jumper WiresCutoff LengthWire Part NumberBulk Wire Part NumberInches (mm)Wire GaugeWG-16-0-6INWG-16-0-10006 (152)16 gaWG-16-0-8INWG-16-0-10008 (203)16 gaWG-16-0-12INWG-16-0-100012 (305)16 ga703-92132WG-10-0-10009 (228)10 ga703-92096WB-4-0-50010 (254)4 gaWG-16-0-6INWG-16-0-10006 (152)16 gaG-5.CONDUIT FABRICATION.Conduit for the broom hood wiring harness is fabricated from bulk PVC pipe stock, P/N A52AE12. Cut conduit using afine-toothed hacksaw or suitable cutting device. Drill endcaps with a drill and 1/2" drill bit. Coupling, P/N E940D can beused for repair of damaged conduit. Refer to paragraph 4-78 for installation instructions.Table G-3. Conduit FabricationPVCBulk PVCCutoff LengthPart NumberPart NumberInches (mm)QuantityFitting AFitting B402-92109A52AE122 (51)1401-005N/A402-92111A52AE1248.5 (1221)2401-005406-005E402-92110A52AE1216 (406)2406-005E447-005G-2