TM 5-3825-230-14&P
G-4.
ELECTRICAL GROUND AND JUMPER WIRES FABRICATION.
There are six ground and jumper wires in the electrical system. Locations are shown in the RPSTL, figures 32, 34, and
35. Refer to paragraph 4-83 for terminal or connector installation.
Table G-2. Ground and Jumper Wires
Cutoff Length
Wire Part Number
Bulk Wire Part Number
Inches (mm)
Wire Gauge
WG-16-0-6IN
WG-16-0-1000
6 (152)
16 ga
WG-16-0-8IN
WG-16-0-1000
8 (203)
16 ga
WG-16-0-12IN
WG-16-0-1000
12 (305)
16 ga
703-92132
WG-10-0-1000
9 (228)
10 ga
703-92096
WB-4-0-500
10 (254)
4 ga
WG-16-0-6IN
WG-16-0-1000
6 (152)
16 ga
G-5.
CONDUIT FABRICATION.
Conduit for the broom hood wiring harness is fabricated from bulk PVC pipe stock, P/N A52AE12. Cut conduit using a
fine-toothed hacksaw or suitable cutting device. Drill endcaps with a drill and 1/2" drill bit. Coupling, P/N E940D can be
used for repair of damaged conduit. Refer to paragraph 4-78 for installation instructions.
Table G-3. Conduit Fabrication
PVC
Bulk PVC
Cutoff Length
Part Number
Part Number
Inches (mm)
Quantity
Fitting A
Fitting B
402-92109
A52AE12
2 (51)
1
401-005
N/A
402-92111
A52AE12
48.5 (1221)
2
401-005
406-005E
402-92110
A52AE12
16 (406)
2
406-005E
447-005
G-2