TM 5-3815-224-14&P
UNIT PREVENTIVE MAINTENANCE CHECKS AND SERVICES
M - MONTHLY
Q - QUARTERLY
S - SEMIANNUALLY
A - ANNUALLY
B - BIENNIALLY
H - HOURS
MI - MILES
ITEM
INTERVAL
ITEM TO BE INSPECTED
NO.
PROCEDURE: CHECK FOR AND HAVE REPAIRED, FILLED, OR ADJUSTED AS NEEDED
M
Q
S
A
B
H
MI
PERFORM ALL OPERATOR PMCS FIRST
1
X
BOOM JIB AND INSERT:
Check for bent chord and lattice IAW the instructions and
standards in appendix.
WARNING!!
Use leather gloves when handling wire rope.
2
X
WIRE ROPE:
Check for wire rope for wear IAW the instructions and standards in
appendix.
STA FORM 667
PREVIOUS EDITION IS OBSOLETE
1 JULY 86
B-17