Figure 7. O-rings.
Figure 9. Tiedown Straps.

Field Maintenance Manual For Military 621G Scraper -6 Page Navigation
  1091    1092    1093    1094    1095  1096  1097    1098    1099    1100    1101  
img
.
TM 5-3805-296-23-6
0436
INSTALLATION CONTINUED
WARNING
Allow hydraulic system to cool before performing procedure. Hot hydraulic fluid can cause
severe burns. Wear eye, hand, and skin protection when working with heated parts.
Hydraulic oil is very slippery. Immediately wipe up any spills. Failure to follow this warning
may result in injury or death to personnel.
3. Install bowl up solenoid (Figure 8, Item 6), washer (Figure 8, Item 3), and bolt (Figure 8, Item 4) on rear main
control valve (Figure 8, Item 5). Do not tighten bolt at this time.
4. Install ladder clamp (Figure 8, Item 7), washer (Figure 8, Item 1), and bolt (Figure 8, Item 2) on bowl up
solenoid (Figure 8, Item 6), tighten bolts (Figure 8, Items 2 and 4).
Figure 8. Bowl Up Solenoid.