img
.
TM 5-3805-296-23-6
0436
REMOVAL CONTINUED
NOTE
Note location of O-rings to aid in installation.
9. Remove two small O-rings (Figure 7, Item 1) from bowl up solenoid (Figure 7, Item 2). Discard O-rings.
10. Remove large O-ring (Figure 7, Item 3) from bowl up solenoid (Figure 7, Item 2). Discard O-ring.
Figure 7. O-rings.
0436
END OF TASK
CLEANING AND INSPECTION
000436
1. Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0539).
2. Clean and inspect all components IAW Electrical General Maintenance Instructions (WP 0540).
END OF TASK
INSTALLATION
000436
NOTE
Install O-rings as noted during removal.
1. Install new large O-ring (Figure 7, Item 3) on bowl up solenoid (Figure 7, Item 2).
2. Install two new small O-rings (Figure 7, Item 1) on bowl up solenoid (Figure 7, Item 2).
0436-7