Figure 13. Test Port.
Figure 15. Test Port.

Field Maintenance Manual For Military 621G Scraper -6 Page Navigation
  492    493    494    495    496  497  498    499    500    501    502  
img
.
TM 5-3805-296-23-6
0405
DISASSEMBLY CONTINUED
NOTE
Note location and position of fitting to aid in installation.
7. Loosen jam nut (Figure 14, Item 7) and remove fitting (Figure 14, Item 1) and O-ring (Figure 14, Item 6) from
leveling valve (Figure 14, Item 2). Discard O-ring.
8. Loosen jam nut (Figure 14, Item 3) and remove fitting (Figure 14, Item 5) and O-ring (Figure 14, Item 4) from
leveling valve (Figure 14, Item 2). Discard O-ring.
Figure 14. Leveling Valve Fittings.
0405
END OF TASK
CLEANING AND INSPECTION
000405
1. Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0539).
2. Clean and inspect all components IAW Electrical General Maintenance Instructions (WP 0540).
END OF TASK
0405-14