Figure 5. Pressure Switch to Center Union Block Line.
Figure 7. Air Valve to Outboard Union Block Line.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  972    973    974    975    976  977  978    979    980    981    982  
img
.
TM 5-3805-296-23-5
0359
REMOVAL CONTINUED
CAUTION
Plug and cap all air lines and fittings to prevent contamination. Failure to follow this
caution may result in equipment damage.
NOTE
Tag and mark air lines to aid in installation.
Note location and quantity of tiedowns to aid in installation.
18. Remove tiedown strap (Figure 6, Item 7) from air line (Figure 6, Item 4) and machine wiring harness
(Figure 6, Item 8). Discard tiedown strap.
19. Remove tube nut (Figure 6, Item 3) from fitting (Figure 6, Item 2).
20. Remove tube nut (Figure 6, Item 6) from fitting (Figure 6, Item 5).
21. Remove air line (Figure 6, Item 4) from fittings (Figure 6, Items 2 and 5).
22. Remove fitting (Figure 6, Item 2) from inboard union block (Figure 6, Item 1).
Figure 6. Differential Lock Solenoid Line.
0359
0359-7