TM 5-3805-296-23-5
0342
REMOVAL CONTINUED
CAUTION
Plug and cap all air hoses and fittings to prevent contamination. Failure to follow this
caution may result in equipment damage.
NOTE
Tag and mark air hoses to aid in installation.
Note routing and location of air hoses to aid in installation.
3. Loosen two tube nuts (Figure 2, Items 1 and 3) on air hose (Figure 2, Item 2).
4. Remove air hose (Figure 2, Item 2) from machine.
Figure 2. Quick-Release Valve to Right Actuator Hose.
0342