Figure 39. Air Tank Connection.
Figure 41. Scraper Air Hoses.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  693    694    695    696    697  698  699    700    701    702    703  
img
.
TM 5-3805-296-23-5
0341
BOWL AIR HOSES REMOVAL CONTINUED
CAUTION
Plug and cap all air tubes and fittings to prevent contamination. Failure to follow this
caution may result in equipment damage.
NOTE
Tag and mark air hoses to aid in installation.
Note routing and location of air hoses to aid in installation.
34. Loosen tube nut (Figure 40, Item 2) and remove air hose (Figure 40, Item 1) from fitting (Figure 40, Item 3).
Figure 40. Air Relay Connection.
0341