Figure 23. Quick-Release Valve.
Figure 25. Air Pressure Sensor Relay.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  629    630    631    632    633  634  635    636    637    638    639  
img
.
TM 5-3805-296-23-5
0337
INSTALLATION CONTINUED
16. Do not disconnect connector (Figure 24, Item 3) from air pressure sensor (Figure 24, Item 4).
17. Position relay (Figure 24, Item 2) and air pressure sensor (Figure 24, Item 4) on machine.
18. Install new O-ring (Figure 24, Item 6) and air pressure sensor (Figure 24, Item 4) on fitting (Figure 24, Item 5).
19. Apply sealant to air hose (Figure 24, Item 1), install air hose on fitting (Figure 24, Item 7), tighten tube nut
(Figure 24, Item 8).
Figure 24. Air Pressure Sensor Relay and Sensor.
0337
0337-25