• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 22. Brake Relay.
Figure 24. Air Pressure Sensor Relay and Sensor.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  628    629    630    631    632  633  634    635    636    637    638  
img
.
TM 5-3805-296-23-5
0337
INSTALLATION CONTINUED
14. Position quick-release valve (Figure 23, Item 1) on mounting bracket (Figure 23, Item 4).
15. Install two washers (Figure 23, Item 3) and bolts (Figure 23, Item 2) on quick-release valve (Figure 23, Item 1)
and mounting bracket (Figure 23, Item 4).
Figure 23. Quick-Release Valve.
0337
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
CAUTION
Do not disconnect jumper harness from air pressure sensor. Air pressure sensor damage
will occur.
NOTE
Remove plugs and caps from air hoses and fittings.
Install air hoses as tagged and marked during removal.
0337-24


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.