Figure 4. Battery Disconnect Ground Bus Bar.
DISCONNECT BATTERY GROUND

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  292    293    294    295    296  297  298    299    300    301    302  
img
. .
TM 5-3805-296-23-5
0312
INSTALLATION CONTINUED
NOTE
Route and install cables as noted during removal.
4. Install ground cable (Figure 5, Item 6), new lockwasher (Figure 5, Item 2), and nut (Figure 5, Item 3) on battery
disconnect switch (Figure 5, Item 9).
5. Install arctic start aid negative battery cable (Figure 5, Item 8), negative battery cable (Figure 5, Item 4), new
lockwasher (Figure 5, Item 7), and nut (Figure 5, Item 5) on battery disconnect switch (Figure 5, Item 9).
6. Position cover (Figure 5, Item 1) on battery disconnect switch (Figure 5, Item 9).
Figure 5. Battery Disconnect Ground Cables.
0312
END OF TASK
FOLLOW-ON TASKS
000312
Connect battery ground (WP 0313).
END OF TASK
END OF WORK PACKAGE