Figure 2. Battery Disconnect Ground Bus Bar.
Figure 4. Battery Disconnect Ground Bus Bar.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  290    291    292    293    294  295  296    297    298    299    300  
img
.
TM 5-3805-296-23-5
0312
REMOVAL CONTINUED
NOTE
Note lockout switch and battery disconnect switch orientation to aid in installation.
5. Remove nut (Figure 3, Item 4), lockwasher (Figure 3, Item 1), and lockout switch (Figure 3, Item 5) from battery
disconnect switch (Figure 3, Item 3). Discard lockwasher.
6. Remove battery disconnect switch (Figure 3, Item 3) from bracket (Figure 3, Item 2).
Figure 3. Negative Junction Block.
0312
END OF TASK
CLEANING AND INSPECTION
000312
1. Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0539).
2. Clean and inspect all components IAW Electrical General Maintenance Instructions (WP 0540).
END OF TASK
0312-4