Figure 13. Left Starter Cable P-clamps and Guard.
Figure 15. Junction Block.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  257    258    259    260    261  262  263    264    265    266    267  
img
.
TM 5-3805-296-23-5
0310
JUNCTION BLOCK REMOVAL
000310
NOTE
Note cable routing to aid in installation.
Tag and mark all electrical connections to aid in installation.
1. Position three covers (Figure 14, Item 1) aside.
2. Remove three nuts (Figure 14, Item 2) and washers (Figure 14, Item 3) from junction block terminals
(Figure 14, Item 4).
3. Remove five cables (Figure 14, Item 8) from junction block terminals (Figure 14, Item 4).
4. Remove two bolts (Figure 14, Item 5) and washers (Figure 14, Item 6) from junction block (Figure 14, Item 7).
5. Remove junction block (Figure 14, Item 7) from machine.
Figure 14. Junction Block.
0310
END OF TASK
CLEANING AND INSPECTION
000310
Clean and inspect all battery cables IAW TM 9-6140-200-13.
END OF TASK
0310-15