Figure 6. Positive Battery Cable Mounting Behind Batteries.
Figure 8. Positive Battery Cable Junction Block.

Field Maintenance Manual For Military 621G Scraper -5 Page Navigation
  198    199    200    201    202  203  204    205    206    207    208  
img
.
TM 5-3805-296-23-5
0307
POSITIVE BATTERY CABLE REMOVAL CONTINUED
NOTE
Tag and mark all cables to aid in installation.
5. Lower crankcase guard (WP 0374).
6. Remove nut (Figure 7, Item 1), washer (Figure 7, Item 4), and P-clamp (Figure 7, Item 2) from mounting stud
(Figure 7, Item 3) and position aside.
7. Remove washer (Figure 7, Item 5), stud (Figure 7, Item 3), washer (Figure 7, Item 6), and P-clamp (Figure 7,
Item 8) and position aside.
Figure 7. Positive Battery Cable Inner Frame Mounting.
0307
0307-9