TM 5-3805-296-23-4
0289
INSTALLATION CONTINUED
NOTE
Install wiring harness as noted during removal.
Install new tiedown strap as noted during removal.
7. Connect converter oil temperature sensor connector (Figure 5, Item 1) to engine interface wiring harness
connector (Figure 5, Item 3).
8. Install new tiedown strap (Figure 5, Item 2) on converter oil temperature sensor connector (Figure 5, Item 1).
9. Remove drain pan from under machine.
Figure 5. Converter Oil Temperature Sensor Harness.
0289
END OF TASK
FOLLOW-ON TASKS
000289
2. Verify correct transmission fluid level (TM 5-3805-296-10).
3. Verify correct operation of machine (TM 5-3805-296-10).
END OF TASK
END OF WORK PACKAGE