0276
REMOVAL CONTINUED
NOTE
Cap and plug all lines and fittings to prevent fluid loss.
Note routing of hydraulic lines to aid in installation.
Mark and tag hydraulic lines to aid in installation.
53. Remove eight bolts (Figure 17, Item 1), washers (Figure 17, Item 2), four flange halves (Figure 17, Item 5), and
transmission cooler lines (Figure 17, Item 6) from machine.
54. Cap and plug transmission cooler lines (Figure 17, Item 6).
55. Remove two O-rings from transmission cooler lines (Figure 17, Items 3 and 4). Discard O-rings.
Figure 17. Transmission Cooler Lines.