Figure 3. Upshift Connector.
Figure 5. Downshift Connector.

Field Maintenance Manual For Military 621G Scraper -4 Page Navigation
  820    821    822    823    824  825  826    827    828    829    830  
img
.
TM 5-3805-296-23-4
0274
UPSHIFT SOLENOID REMOVAL CONTINUED
3. Remove locknut (Figure 4, Item 2) and washer (Figure 4, Item 1) from upshift solenoid (Figure 4, Item 3).
Discard locknut.
4. Remove upshift solenoid (Figure 4, Item 3) from machine.
Figure 4. Upshift Solenoid.
0274
END OF TASK