TM 5-3805-296-23-4
0272
INSTALLATION CONTINUED
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may cause injury to personnel.
NOTE
Remove plugs and caps from hoses and fittings.
Install hoses as noted during removal.
22. Position hoses (Figure 22, Item 9) on machine.
23. Install new O-ring (Figure 22, Item 5), hose (Figure 22, Item 9), two flange halves (Figure 22, Item 6), four
washers (Figure 22, Item 7), and bolts (Figure 22, Item 8) on line (Figure 22, Item 3).
24. Apply sealing compound to threads of plug (Figure 22, Item 4).
25. Install plug (Figure 22, Item 4) on line (Figure 22, Item 3).
26. Install new O-ring (Figure 22, Item 2) and sensor (Figure 22, Item 1) on line (Figure 22, Item 3).
Figure 22. Sensor and Plug.
0272