• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 3. Differential Lock Solenoid Bolts.
DIFFERENTIAL LOCK SOLENOID REPLACEMENT - Continued

Field Maintenance Manual For Military 621G Scraper -4 Page Navigation
  775    776    777    778    779  780  781    782    783    784    785  
img
.
TM 5-3805-296-23-4
0271
REMOVAL CONTINUED
NOTE
Note position of fittings to aid in assembly.
Note location and quantity of tiedowns to aid in installation.
7. Remove two tiedown straps (Figure 4, Item 5) from differential lock solenoid wiring (Figure 4, Item 1). Discard
tiedown strap.
8. Remove fitting (Figure 4, Item 2) from differential lock solenoid (Figure 4, Item 3).
9. Remove fitting (Figure 4, Item 4) from differential lock solenoid (Figure 4, Item 3).
Figure 4. Fittings.
0271
END OF TASK
CLEANING AND INSPECTION
000271
1. Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0539).
2. Clean and inspect all components IAW Electrical General Maintenance Instructions (WP 0540).
END OF TASK