Figure 7. Quick Release Connection.
DIFFERENTIAL LOCK SOLENOID AIR HOSE REPLACEMENT - Continued

Field Maintenance Manual For Military 621G Scraper -4 Page Navigation
  761    762    763    764    765  766  767    768    769    770    771  
img
.
TM 5-3805-296-23-4
0270
REMOVAL CONTINUED
CAUTION
Plug and cap air hose and fitting to prevent contamination. Failure to follow this caution
may result in equipment damage.
12. Loosen tube nut (Figure 8, Item 1) and remove differential air hose (Figure 8, Item 3) from fitting
(Figure 8, Item 2).
13. Loosen tube nut (Figure 8, Item 4) and remove differential air hose (Figure 8, Item 3) from fitting
(Figure 8, Item 5) and machine.
Figure 8. Differential Connection.
0270
END OF TASK
CLEANING AND INSPECTION
000270
Clean and inspect all components IAW Mechanical General Maintenance Instructions (WP 0539).
END OF TASK
0270-9