TM 5-3805-296-23-4
0270
REMOVAL CONTINUED
CAUTION
Plug and cap air hose and fitting to prevent contamination. Failure to follow this caution
may result in equipment damage.
NOTE
Tag and mark air hose to aid in installation.
Note routing of air hose to aid in installation.
10. Loosen tube nut (Figure 7, Item 2) and remove differential lock solenoid air hose (Figure 7, Item 1) from fitting
(Figure 7, Item 3).
11. Remove differential lock solenoid air hose (Figure 7, Item 1) from machine.
Figure 7. Quick Release Connection.
0270