TM 5-3805-296-23-4
0255
INSTALLATION CONTINUED
12. Install three new seals (Figure 26, Items 2 and 3) on upper coolant tank (Figure 26, Item 1).
WARNING
Contact with rubber lubricant can damage skin. Wear gloves when handling rubber
lubricant. If rubber lubricant contacts skin, wash it off immediately.
Rubber lubricant is very slippery. Immediately wipe up any spills.
Failure to follow these warnings may result in injury or death to personnel.
13. Apply rubber lubricant to three seals (Figure 26, Items 2 and 3).
Figure 26. Upper Coolant Tank Seals.
0255