16. Install new O-ring (Figure 26, Item 2) on HVAC hose (Figure 26, Item 1).
Figure 26. HVAC Hose and O-ring.
0254
17. Install HVAC hose (Figure 27, Item 3) on fitting (Figure 27, Item 2), and tighten tube nut (Figure 27, Item 1).
Figure 27. HVAC Hose and Fitting.
0254