1. Install blue low-side hose (Figure 3, Item 5) on suction (low) side of A/C compressor (Figure 3, Item 3).
2. Install red high-side hose (Figure 3, Item 4) on discharge (high) side of A/C compressor (Figure 3, Item 3).
3. Follow recovery station OEM instructions and charge A/C system with R-134a refrigerant. Refrigerant capacity
is 3.3 lb (1.5 kg).
4. Once charging is complete, disconnect blue low-side hose (Figure 3, Item 5) from suction (low) side (Figure 3,
Item 1) of A/C compressor (Figure 3, Item 3) and red high-side hose (Figure 3, Item 4) from discharge (high)
side (Figure 3, Item 2) of A/C compressor (Figure 3, Item 3).
5. Operate A/C system to verify correct operation (TM 5-3805-296-10).