TM 5-3805-296-23-4
0244
REMOVAL CONTINUED
3. Slide lock tab (Figure 2, Item 2) to unlock position, disconnect atmospheric pressure sensor wiring harness
connector (Figure 2, Item 1) from atmospheric pressure sensor (Figure 2, Item 3).
4. Remove atmospheric pressure sensor (Figure 2, Item 3) from housing (Figure 2, Item 4).
5. Remove O-ring (Figure 2, Item 5) from atmospheric pressure sensor (Figure 2, Item 3). Discard O-ring.
Figure 2. Atmospheric Pressure Sensor.
0244
END OF TASK
CLEANING AND INSPECTION
000244
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0539).
END OF TASK
INSTALLATION
000244
NOTE
Install wiring harness connector as noted during removal.
1. Install new O-ring (Figure 2, Item 5) on atmospheric pressure sensor (Figure 2, Item 3).
2. Install atmospheric pressure sensor (Figure 2, Item 3) on housing (Figure 2, Item 4).
3. Connect atmospheric pressure sensor wiring harness connector (Figure 2, Item 1) to atmospheric pressure
sensor (Figure 2, Item 3), and slide lock tab (Figure 2, Item 2) into position.