TM 5-3805-296-23-4
0231
LOWER AIR LINE INSTALLATION CONTINUED
WARNING
Use caution when using adhesives and sealants. Prolonged inhalation of vapors can
cause lung irritation. Contact with skin can cause dermatitis. Wear gloves and safety
goggles and use product in a well-ventilated area away from open flame. If ingested, keep
individual calm and seek medical attention. DO NOT induce vomiting. If contact with skin
or eyes is made, flush thoroughly with water. Dispose of cleanup rags IAW local policy and
ordinances. Failure to follow this warning may result in injury to personnel.
NOTE
Install fittings as noted during removal.
11. Apply sealing compound to threads of adapter (Figure 24, Item 5).
12. Install adapter (Figure 24, Item 5) on elbow (Figure 24, Item 4).
13. Apply sealing compound to threads of fitting (Figure 24, Item 1).
14. Install fitting (Figure 24, Item 1) on adapter (Figure 24, Item 5).
NOTE
Install hose as noted during removal.
15. Install ether start hose (Figure 24, Item 3) and nut (Figure 24, Item 2) on fitting (Figure 24, Item 1).
Figure 24. Sealing Compound and Ether Start Hose.
0231