Figure 11. Headlamp Breaker and Wiring.
Table 1. All Lights, Horn, and Backup Alarm Fail To Operate Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  996    997    998    999    1000  1001  1002    1003    1004    1005    1006  
img
.
TM 5-3805-296-23-2
0141
Table 1. All Lights, Horn, and Backup Alarm Fail To Operate Continued.
0141
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 30. Test for Shorted 539
All Lights, Horn, and Backup
Circuit.
Alarm Fail To Operate
1. Turn mode switch on military light
Continued
switch to OFF position
(TM 5-3805-296-10).
2. Separate boot (Figure 12, Item 1)
from turn signal switch
(Figure 12, Item 2).
3. Disconnect terminal 539
(Figure 12, Item 4) from turn
signal switch terminal 5
(Figure 12, Item 3).
Figure 12. Turn Signal Switch and Wiring Harness.
0141
4. Have assistant start engine
(TM 5-3805-296-10). Allow air
supply pressure gauge to reach
normal operating pressure before
proceeding (TM 5-3805-296-10).
5. Have assistant turn mode switch
on military light switch to
SER. DRIVE position
(TM 5-3805-296-10).