Table 1. Dome Lamp Does Not Operate Continued.
Figure 5. Installing Dome Lamp.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  955    956    957    958    959  960  961    962    963    964    965  
img
.
TM 5-3805-296-23-2
0139
Table 1. Dome Lamp Does Not Operate Continued.
0139
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Dome Lamp Does Not
4. Turn battery disconnect switch to
Operate Continued
ON position (TM 5-3805-296-10).
5. Turn mode switch on military light
switch to SER. DRIVE position
(TM 5-3805-296-10).
6. Using digital multimeter
Voltage 18 to 26 V Proceed to step 7.
(WP 0540), test for voltage
Voltage Less Than 18 V Replace
between door switch terminal 1
headliner wiring harness (WP 0497).
(WP 0012, Figure 230) and
Proceed to Test Step 5.
ground.
7. Using digital multimeter
Voltage 18 to 26 V Replace headliner
(WP 0540), test for voltage
wiring harness (WP 0497).
between door switch terminal 2
Proceed to Test Step 5.
(WP 0012, Figure 230) and
Voltage Less Than 18 V Replace
ground.
door switch (WP 0472).
Proceed to Test Step 5.
Test Step 5. Verify Malfunction is
Resolved.
1. Ensure all harness connectors are
connected.
2. If removed, install cover
(Figure 4, Item 2) and screw
(Figure 4, Item 1) on bracket
(Figure 4, Item 3).
Figure 4. Door Switch.