TM 5-3805-296-23-2
0138
Table 1. One or More Park Lights Do Not Operate Continued.
0138
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
One or More Park Lights Do
Test Step 3. Test for Open Military
Not Operate Continued
Light Switch.
1. Turn mode switch on military light
switch to OFF position
(TM 5-3805-296-10).
2. Turn battery disconnect switch to
OFF position (TM 5-3805-296-10).
3. Disconnect connector H-C9
(WP 0012, Figure 242) from
military light switch (WP 0012,
Figure 241).
4. Turn mode switch on military light
switch to SER. DRIVE position
(TM 5-3805-296-10).
(WP 0540), measure resistance
Proceed to Test Step 4.
between military light switch
terminal F and terminal H
Replace military light switch (WP 0517).
(WP 0012, Figure 241).
Proceed to Test Step 26.
Test Step 4. Test Voltage to Signal
Lamp.
1. Turn mode switch on military light
switch to OFF position
(TM 5-3805-296-10).
2. Connect connector H-C9
(WP 0012, Figure 242) to military
light switch (WP 0012,
Figure 241).
3. Disconnect connector L-C5
(WP 0012, Figure 211) from right
front signal lamp (WP 0012,
Figure 210).
4. Turn battery disconnect switch to
ON position (TM 5-3805-296-10).
5. Turn mode switch on military light
switch to SER. DRIVE position
(TM 5-3805-296-10).
Voltage 18 to 26 V Replace right front
(WP 0540), test for voltage
signal lamp (WP 0383).
between connector L-C5
Proceed to Test Step 26.
terminal C and terminal B
Voltage Less Than 18 V Proceed to
(WP 0012, Figure 211).
Test Step 5.
0138-3