TM 5-3805-296-23-2
0134
Table 1. Blower Motor Does Not Operate in One or More Speeds Continued.
0134
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 31. Test Air Conditioner
Blower Motor Does Not
Operate in One or More
or Open.
Speeds Continued
1. Remove HVAC access cover
(WP 0479).
2. Loosen wingnut (Figure 10, Item 5)
and remove plate (Figure 10,
Item 6) and filter (Figure 10,
Item 7) from HVAC assembly
(Figure 10, Item 4).
3. Remove four bolts (Figure 10,
Item 1) and washers (Figure 10,
Item 2) from HVAC assembly
(Figure 10, Item 4).
4. Remove bolt (Figure 14, Item 8),
washer (Figure 14, Item 9) and
bracket (Figure 14, Item 10) from
front plate (Figure 14, Item 3) and
HVAC assembly. (Figure 14,
Item 4).
Figure 14. Front Plate.
0134