Table 1. Response of All Implements Too Slow, Cushion Hitch Operates Normally Continued.
Table 1. Response of All Implements Too Slow, Cushion Hitch Operates Normally Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  781    782    783    784    785  786  787    788    789    790    791  
img
.
TM 5-3805-296-23-2
0125
Table 1. Response of All Implements Too Slow, Cushion Hitch Operates Normally Continued.
0125
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Assemble test gauge and hose as
Response of All Implements
follows:
Too Slow, Cushion Hitch
a. Apply sealing compound to
Operates Normally
Continued
threads of gauge
(Figure 4, Item 3).
b. Install nipple (Figure 4, Item 4)
on gauge (Figure 4, Item 3).
c.
Connect hose quick
disconnect coupling
(Figure 4, Item 5) to nipple
(Figure 4, Item 4).
d. Remove cover
(Figure 4, Item 6) from test
port (Figure 4, Item 1).
e. Connect hose quick
disconnect coupling
(Figure 4, Item 2) to test port
(Figure 4, Item 1).
f.
Position gauge
(Figure 4, Item 3) where it can
be easily read away from
machine.
Figure 4. Assembling Test Gauge and Hose.
0125