Table 1. 1277 Apron Raise Proportional Solenoid Diagnostic Codes Continued.
Table 1. 1277 Apron Raise Proportional Solenoid Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -2 Page Navigation
  105    106    107    108    109  110  111    112    113    114    115  
img
.
TM 5-3805-296-23-2
0072
Table 1. 1277 Apron Raise Proportional Solenoid Diagnostic Codes Continued.
072
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 1. Test for Shorted Apron
1277-06 Apron Raise
Raise Solenoid.
Solenoid Current Above
1. Turn ignition switch and battery
Normal Continued
disconnect switch to OFF position
(TM 5-3805-296-10).
2. Remove four bolts
(Figure 5, Item 2), washers
(Figure 5, Item 1), and front cover
(Figure 5, Item 3) from machine.
Figure 5. Front Cover.
0072
3. Disconnect connector F-C2
(WP 0012, Figure 150) from apron
raise solenoid connector
(WP 0012, Figure 149).
4. Turn battery disconnect switch and
ignition switch to ON position
(TM 5-3805-296-10).
0072-13