Figure 15. Instrument Panel Cover and Retaining Hardware.
Table 1. 0590 Communication Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  876    877    878    879    880  881  882    883    884    885    886  
img
. . . .
TM 5-3805-296-23-1
0061
Table 1. 0590 Communication Diagnostic Codes Continued.
061
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
6. Remove two bolts
0590-09 Engine Control
(Figure 16, Item 1) and left vent
Module Abnormal Update
(Figure 16, Item 2) from instrument
Rate Continued
panel (Figure 16, Item 3).
7. Remove two bolts
(Figure 16, Item 6) and right vent
(Figure 16, Item 7) from instrument
panel (Figure 16, Item 3).
8. Remove six bolts
(Figure 16, Item 4) from instrument
panel (Figure 16, Item 3) and
ROPS (Figure 16, Item 5).
Position instrument panel to
access connector P-C18
(WP 0012, Figure 269).
Figure 16. Instrument Panel and Retaining Hardware.
0061
9. Disconnect connector P-C18
(WP 0012, Figure 269) from tractor
operator monitor.
10. Using digital multimeter
Resistance 5.0 Ohms or Less
(WP 0540), measure resistance
Proceed to Test Step 16.
between connector W-C16
Resistance Greater Than 5.0 Ohms
terminal 1 and terminal 2
Replace main cab wiring harness
(WP 0012, Figure 87).
(WP 0505).
Proceed to Test Step 20.
0061-28