Table 1. 0590 Communication Diagnostic Codes Continued.
Table 1. 0590 Communication Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  880    881    882    883    884  885  886    887    888    889    890  
img
. . . . . . . . . . . . . . . .
TM 5-3805-296-23-1
0061
Table 1. 0590 Communication Diagnostic Codes Continued.
061
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
3. Using digital multimeter
0590-09 Engine Control
Continuity Replace main cab wiring
(WP 0540), test for continuity
Module Abnormal Update
harness (WP 0505). Install circuit
between the following:
Rate Continued
breaker F14 on circuit breaker panel
a. Connector W-C8 terminal 27
(TM 5-3805-296-10).
(WP 0012, Figure 282) and all
Proceed to Test Step 20.
other terminals in connector
No Continuity Proceed to step 4.
W-C8 (WP 0012, Figure 282).
b. Connector W-C8 terminal 28
(WP 0012, Figure 282) and all
other terminals in connector
W-C8 (WP 0012, Figure 282).
c.
Connector W-C8 terminal 29
(WP 0012, Figure 282) and all
other terminals in connector
W-C8 (WP 0012, Figure 282).
4. Using digital multimeter
Continuity Replace main cab wiring
(WP 0540), test for continuity
harness (WP 0505). Install circuit
between the following:
breaker F14 on circuit breaker panel
a. Connector W-C8 terminal 27
(TM 5-3805-296-10).
(WP 0012, Figure 282) and
Proceed to Test Step 20.
ground.
No Continuity Proceed to Test
Step 19.
b. Connector W-C8 terminal 28
(WP 0012, Figure 282) and
ground.
c.
Connector W-C8 terminal 29
(WP 0012, Figure 282) and
ground.
Test Step 19. Test for Shorted Engine
Interface Wiring Harness.
1. Disconnect connector
CM-C1 (WP 0012,
Figure 30) from engine
ECM.
2. Using digital multimeter
Continuity Replace engine interface
(WP 0540), test for continuity
wiring harness (WP 0211). Install circuit
between the following:
breaker F14 on circuit breaker panel
a. Connector CL-C3 terminal 11
(TM 5-3805-296-10).
(WP 0012, Figure 86) and all
Proceed to Test Step 20.
other terminals in connector
No Continuity Proceed to step 3.
CL-C3 (WP 0012, Figure 86).
b. Connector CL-C3 terminal 18
(WP 0012, Figure 86) and all
other terminals in connector
CL-C3 (WP 0012, Figure 86).
c.
Connector CL-C3 terminal 20
(WP 0012, Figure 86) and all
other terminals in connector
CL-C3 (WP 0012, Figure 86).
0061-32