TM 5-3805-296-23-1
0033
Table 1. 0274 Atmospheric Pressure Sensor Diagnostic Codes Continued.
033
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
0274-04 Atmospheric
Test Step 4. Verify Malfunction is
Pressure Sensor Voltage
Resolved.
Below Normal Continued
1. Ensure all harness connectors are
connected.
2. At MSD, check for active
274-4 Atmospheric Pressure Sensor
Voltage Below Normal Becomes
Inactive Troubleshooting complete.
274-4 Atmospheric Pressure Sensor
Voltage Below Normal Remains
Active Repeat troubleshooting from
the beginning.
3. Install splash shield
(Figure 4, Item 4), four bushings
(Figure 4, Item 3), washers
(Figure 4, Item 2), and bolts
(Figure 4, Item 1) on machine.
Figure 4. Splash Shield and Retaining Hardware.
0033
4. Install left frame access plate
(WP 0376).
5. Troubleshooting complete.
END OF WORK PACKAGE