• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. 0274 Atmospheric Pressure Sensor Diagnostic Codes Continued.
Table 1. 0274 Atmospheric Pressure Sensor Diagnostic Codes Continued.

Field Maintenance Manual For Military 621G Scraper -1 Page Navigation
  611    612    613    614    615  616  617    618    619    620    621  
img
. .
TM 5-3805-296-23-1
0033
Table 1. 0274 Atmospheric Pressure Sensor Diagnostic Codes Continued.
033
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 7. Verify Malfunction is
0274-03 Atmospheric
Resolved.
Pressure Sensor Voltage
1. Ensure all harness connectors are
Above Normal Continued
connected.
2. At MSD, check for active
274-3 Atmospheric Pressure Sensor
Voltage Above Normal Becomes
diagnostic codes (WP 0008).
Inactive Proceed to step 3.
274-3 Atmospheric Pressure Sensor
Voltage Above Normal Remains
Active Repeat troubleshooting from
the beginning.
3. Install splash shield
(Figure 2, Item 4), four bushings
(Figure 2, Item 3), washers
(Figure 2, Item 2), and bolts
(Figure 2, Item 1) on machine.
Figure 2. Splash Shield and Retaining Hardware.
0033
4. Install left frame access plate
(WP 0376).
5. Troubleshooting complete.
0033-6