TM 5-3805-296-23-1
0033
Table 1. 0274 Atmospheric Pressure Sensor Diagnostic Codes Continued.
033
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
Test Step 7. Verify Malfunction is
0274-03 Atmospheric
Resolved.
Pressure Sensor Voltage
1. Ensure all harness connectors are
Above Normal Continued
connected.
2. At MSD, check for active
274-3 Atmospheric Pressure Sensor
Voltage Above Normal Becomes
Inactive Proceed to step 3.
274-3 Atmospheric Pressure Sensor
Voltage Above Normal Remains
Active Repeat troubleshooting from
the beginning.
3. Install splash shield
(Figure 2, Item 4), four bushings
(Figure 2, Item 3), washers
(Figure 2, Item 2), and bolts
(Figure 2, Item 1) on machine.
Figure 2. Splash Shield and Retaining Hardware.
0033
4. Install left frame access plate
(WP 0376).
5. Troubleshooting complete.