TM 5-3805-296-23-1
0025
Table 1. 0172 Intake Manifold Air Temperature Sensor Diagnostic Codes Continued.
025
CID FMI
TEST OR INSPECTION
CORRECTIVE ACTION
0172-03 Intake Manifold Air
Test Step 5. Verify Malfunction is
Temperature Sensor Voltage
Resolved.
Above Normal or Inlet Air
1. Ensure all harness connectors are
Temperature Parameter Is
connected.
40 Continued
2. At MSD, check for active
Temperature Sensor Voltage Above
Normal Becomes Inactive or Inlet Air
Temperature Parameter Other Than
40 Proceed to step 3.
Temperature Sensor Voltage Above
Normal Remains Active or Inlet Air
Temperature Parameter Remains
40 Repeat troubleshooting from the
beginning.
3. If removed, install splash shield
(Figure 2, Item 4), four bushings
(Figure 2, Item 3), washers
(Figure 2, Item 2), and bolts
(Figure 2, Item 1) on machine.
Figure 2. Splash Shield and Retaining Hardware.
0025
4. If lowered, install left frame access
plate (WP 0376).
5. Troubleshooting complete.