INSTALLATION
00017
WARN I N G
Ether fuel is extremely flammable and toxic.DO NOT smoke and make sure you are in a
well-ventilated area away from heat, open flames, or sparks. Wear eye protection. Avoid
contact with skin and eyes and avoid breathing ether fumes. If fluid enters or fumes irritate
the eyes, wash immediately with large quantities of clean water for 15 minutes. Seek
medical attention immediately if ether is inhaled or causes eye irritation.
Ensure gasket is properly s ated in valve prior to installing cylinder. If not, ether will
e
escape from valve. Seek medical attention immediately if ether is inhaled or causes eye
irritation.
Failure to follow this warnng may result in serious injury or death to personnel.
i
1. Install new gasket (Figure 3, Item 1) on valve (Figure 3, Item 2).
2. Install filter (Figure 3, Item 3) on valve (Figure 3, Item 2).