• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 9. Ejector Rollers.
Figure 10. Transmission and Differential Sight Gauge/Oil Fill.

Operators Manual For Military 621G Scraper Page Navigation
  126    127    128    129    130  131  132    133    134    135    136  
img
TM 5-3805-296-10
0012
Table 1. Preventive Maintenance Checks and Services (PMCS) Continued.
ITEM TO BE
CHECKED OR
EQUIPMENT NOT
ITEM
MAN-
NO.
INTERVAL
HOURS
SERVICED
PROCEDURE
READY/AVAILABLE IF:
Front and
Right Side
13
Before
.2
Transmission/
Perform cold check of
Class III leaks are
Differential Oil
transmission and differential
evident.
Level
oil levels:
a. Lift and remove cover plate
from machine.
b. Clean area around sight
gauges and fill caps.
c. Maintain oil levels between
the marks on sight gauges.
d. Remove filler cap(s).
e. Add oil as required through
filler opening(s). Refer to LO
5-3805-296-13 for proper
oil(s) based on outside
temperature. Do NOT overfill.
f. Clean filler cap(s), then
reinstall.
g. Reinstall cover plate.
0012-12


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.