TM 5-3805-296-23-5
0337
REMOVAL CONTINUED
CAUTION
Plug and cap all air hoses and fittings to prevent contamination. Failure to follow this
caution may result in equipment damage.
Do not disconnect jumper harness from air pressure sensor. Air pressure sensor damage
will occur.
NOTE
Tag and mark air hoses to aid in installation.
3. Do not disconnect connector (Figure 2, Item 3) from air pressure sensor (Figure 2, Item 4).
4. Remove air pressure sensor (Figure 2, Item 4) and O-ring (Figure 2, Item 6) from fitting (Figure 2, Item 5).
Discard O-ring.
5. Remove relay (Figure 2, Item 2) and air pressure sensor (Figure 2, Item 4) from machine.
6. Loosen tube nut (Figure 2, Item 8) and remove air hose (Figure 2, Item 1) from fitting (Figure 2, Item 7).
Figure 2. Air Pressure Sensor Relay and Sensor.
0337