9
11
1
3
8
12
1
10
6
TM 9-4940-568-34
5-79
Ensure bottom cover is supported
during removal of rivets or
damage to equipment may result.
NOTE
Note position of bottom cover
and fuel tank pad during removal.
(9)
With the aid of an assistant, remove 26
rivets (8), bottom cover (3) and fuel tank
pad (9) from bottom of generator set (1).
Ensure fuel tank is supported
during removal or damage to
equipment may result.
(10)
With the aid of an assistant, remove nine
locknuts (10), washers (11), screws (12)
and fuel tank (6) from bottom of generator
set (1).
NOTE
If replacing fuel tank, perform
Step (11).
(11)
Remove fuel tank gage from fuel tank
(TM 9-4940-568-20).
b.
Cleaning/Inspection.
Drycleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles, face
shield, and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when
using solvent. The flashpoint for Type II Drycleaning Solvent is 140 degrees F (60 degrees
C) and Type III Drycleaning Solvent is 200 degrees F (93 degrees C). Failure to do so may
result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts
eyes, immediately flush eyes with water and get immediate medical attention.
(1)
Clean fuel tank brackets and generator set supports with drycleaning solvent.
(2)
Clean fuel tank pad with soapy water. Rinse pad with clean water.