TM 9-4940-568-34
3-61
WARNING
Remove pivot shaft only far
enough to release tension link
cylinder and support tension link
upon removal of pivot shaft.
Failure to comply may result in
injury to personnel or damage to
equipment.
(3) With help from assistant, remove pivot
shaft (5) from RH tension link cylinder
(6).
WARNING
Remove pivot shaft only far
enough to release mast and
support mast upon removal of
pivot shaft. Failure to comply
may result in injury to personnel
or damage to equipment.
(4) With help from assistant, remove pivot
shaft (5) from mast (7).
WARNING
Remove pivot shaft only far
enough to release tension link
cylinder and support tension link
upon removal of pivot shaft.
Failure
(5) With help from assistant, remove pivot
shaft (5) from LH tension link cylinder
(8).
(6) Remove screw (9), washer (10), and
bushing (11) from rivet eyebolt (12).
(7) Remove rivet eyebolt (12) from pivot
shaft (13).
WARNING
Remove pivot shaft only far
enough to release lift cylinder
and support lift cylinder upon
removal of pivot shaft. Failure to
comply may result in injury to
personnel
or
damage
to
equipment.
(8) Remove pivot shaft (13) from RH lift
cylinder (14).