TM 9-4940-568-20
7-5
NOTE
Note location and position of
hoses prior to removal.
(4)
Remove two hydraulic hoses (6), fittings (7)
and preformed packings (8) from hydraulic
filter head (5). Discard preformed packings.
(5)
Remove three screws (9), lockwashers (10),
washers (11), and hydraulic filter head (5)
from bracket (12). Discard lockwashers.
(6)
Remove four screws (13), lockwashers (14),
cushioned clamp (15) and bracket (12) from
flywheel housing (16). Discard
lockwashers.
b. Installation.
(1)
Install bracket (12) and cushioned clamp
(15) on flywheel housing (16) and secure
with four lockwashers (14) and screws (13).
(2)
Install hydraulic filter head (5), three
washers (11), new lockwashers (10), and
screws (9) on bracket (12).
NOTE
Install hydraulic hoses in location
and position noted during
removal.
(3)
Apply oil to preformed packings (8).
(4)
Install two preformed packings (8), fittings
(7) and hydraulic hoses (6) on hydraulic
filter head (5).
(5)
Close drain valve (2).
(6)
Install filter (4), preformed packing (3) and
hydraulic filter housing (1) on hydraulic
fitter head (5).
c.
Follow-On Maintenance:
Fill hydraulic reservoir, (Para 7-6).
Connect batteries, (TM 9-4940-568-10).
Start generator and check for leaks,
(TM 9-4940-568-10).
END OF TASK
6
6
7
7
5
9
10
11
12
12
16
15
14
13
5
2
1
4
3
8
8