3
2
1
4
TM 9-4940-568-20
7-3
NOTE
Hydraulic reservoir capacity is 25 gallons.
(2)
Position suitable drain pan under hydraulic reservoir (2), remove drain plug (3) and open drain valve (4).
Drain hydraulic reservoir.
(3)
Close drain valve (4) and install drain plug (3).
b.
Fill.
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful
vapors, and are harmful to skin and clothing. To avoid injury or death, keep away from
open fire and use in well-ventilated area. If adhesive, solvent, or sealing compound
gets on skin or clothing, wash immediately with soap and water.
(1)
Apply sealing compound to threads of drain plug (3).
(2)
Ensure drain valve (4) is closed and install drain plug (3) on drain valve.
(3)
Fill hydraulic reservoir (2) (Para 2-9, Table 2-2).
(4)
Install hydraulic reservoir filler breather cap (1) on hydraulic reservoir (2).
END OF TASK