TM 9-4940-568-20
2-129
Table 2-21. Crane Troubleshooting (CONT).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Test 3.
Remove hoist controller from remote control unit. Refer to paragraph 5-12 in this
manual. Place EMERGENCY STOP switch in ON position. Check for continuity
between the following locations:
From remote control cable connector
pin location:
To controller connector terminal
location:
Check 1
H
8E
Check 2
G
16
Check 3
B
2G
If no continuity is found, repair the wiring within the remote control unit.
If continuity is found, go to Test 4.