1.
2.
3.
4.
5.
6.
7.
8 .
NOTE
Male and female inserts are replaced the same way. This procedure covers male insert
replacement.
Remove receptacle (21) from grommet retaining nut (19).
Remove grommet (22) from receptacle (21). Cut insert (23) from wire (20).
Remove grommet (22), receptacle (21), and grommet retaining nut (19) from cable (18).
Strip insulation off wire (20) equal to depth of new insert (23).
Thread cable (18) through grommet retaining nut (19), receptacle (21), and grommet (22).
Position new insert (23) on wire (20) and solder.
Press grommet (22) into receptacle (21) until seated.
Install receptacle (21) on grommet retaining nut (19).
FOLLOW-ON TASKS:
Connect towing vehicle electrical connector to semitrailer (para 2-10).
Check operation of lights.