INSTALLATION
3.
Install nose box cover (2) on nose box (1) with
eight screws (3).
1.
Position air coupling (9), elbow (10), and reducer
pipe (11) as an assembly in nose box (1). Install
new Iockwasher (6) and nut (5).
2.
Apply antiseize tape to threads of air hose (4) and
connect air hose to male reducer pipe (11).
FOLLOW-ON TASKS:
Perform air leakage test (para 4-37).
TA508034